Water Service Installation Detail
View original document →
Overview
This document is a technical schematic for the installation of a residential water service line, issued by the Borough of Ebensburg. It outlines the specific piping layout, component requirements, and installation standards for connecting a property to the municipal water supply.
Installation Specifications
The diagram details the sequence of components required from the street to the interior of the building:
- Source: The line originates "From Curb Stop. "
- Entry Point: A copper inlet pipe enters through the interior basement wall.
- Valves and Controls:
- A shut-off valve is required immediately after the inlet.
- A pressure reducer must be installed to regulate water pressure.
- Metering:
- A water meter is required with a minimum size of 5/8 inches.
- The meter must be obtained from the Borough.
- A wire connection to a remote readout is required.
- Safety: A backflow preventer must be installed on the line leading to the customer.
Technical Requirements
- Piping Height: The center of the piping must be installed 2' to 4' above the basement floor and 6" from the wall.
- Pipe Size: The minimum pipe size is 3/4", though it should match the existing pipe size.
- Clearance: There must be a minimum of 6" clearance between the pipe and the basement floor.
- Adaptors: A specific "Pipe to Meter Adaptor" is required for the connection.
Administrative Details
- Issuing Authority: Borough of Ebensburg, Pennsylvania.
- Engineering Firm: L. Robert Kimball & Associates, Inc. , based in Ebensburg.
- Revision Date: The document was updated in May 2024.