# Inframark WTP Report

- Summary: Ebensburg Municipal Authority: July 2025 WTP Monthly Report Date: August 25, 2025 Submitted by: Luke Byrne, Inframark Executive Summary & Operations Water Production: The plant treated 36,009,000…
- Source: Ebensburg Borough
- Published: 2025-08-25
- Captured: 2026-08-10T16:42:10.366Z
- Source URL: https://ebensburgpa.com/wp-content/uploads/2025/08/July-2025-operating-report-WTP.pdf
- Content URL: https://ebensburg.site/document/inframark-wtp-report-8-25-2025/
- Content note: This portable copy is not the official record and may include an automated convenience summary. Verify important details in the original document.

Ebensburg Municipal Authority: July 2025 WTP Monthly Report Date: August 25, 2025 Submitted by: Luke Byrne, Inframark Executive Summary & Operations Water Production: The plant treated 36,009,000 gallons of reservoir water in July (avg. 1,161,581 gallons/day). Purchased Water: An average of 231,822 gallons per day were purchased from Saltlick and blended into the system. This volume is higher than normal because Nanty Glo is buying water from Ebensburg. Nanty Glo Interconnect: Nanty Glo shut off their emergency interconnect on July 2nd. They reopened it on July 20th requesting 300 GPM due to a filter failure. Staff have been operating the WTP at full permit capacity to meet demand. Nanty Glo has exceeded the 15-day purchase limit for an emergency interconnect. Reservoir Level: The upper reservoir water level is at -2 ft. Maintenance & Repairs Inframark staff completed 56 work orders in July. Key activities included: Equipment Issues: A Flygt pump in the lagoon wet well suffered a seal failure. The 20-year-old pump was sent to Ram for evaluation; the rebuild cost over 50% of a new unit, so a new pump has been ordered. On July 3rd, the raw water valve was not functioning properly due to a faulty 4-20 mA feedback instrument. A new device was installed and is working correctly. #2 pump at Saltlick tripped on low voltage but has since operated properly. Routine Maintenance: Fire extinguisher and ladder inspections. Sump pumps exercised. DAF Air saturation adjustments and sump level sensor verifications. Lagoon motor pull, vault cleaning, and float adjustments. Greasing of clarifier drives, finished water pumps/motors, and all pump station motors. Cleaning of clarifier troughs, pH/turbidity meters, and the facility. Jar testing to optimize chemical usage. Compliance & Safety Inspections: PA DEP performed their annual water supply inspection on July 22-23. The inspector rated the facility as one of the best operated they inspect. Sampling: Bacteriological: 9 samples collected; zero total coliform positives. Chlorine: 5 samples collected (one per week); all met the minimum requirement of 0. 20mg/L free chlorine. PFAS: Third quarter UCMR5 samples collected with no detects. Safety Record: No accidents occurred in July. Personnel have worked 2,008 days (5 years, 7 months) without an accident or injury. Training: Weekly tailgate meetings and crane truck safety presentations were held. Financial Update Maintenance Expenditures: Hach: $1,170. 19 (pH probe) The Meter Guy LLC: $725. 00 (Annual meter calibrations) Walmart: $246. 01 (Air hose, sampling disinfectants, sump pump) Heritage Environmental: $129. 50 (Chlorine scale repairs) APPLIED: $152. 29 (Raw water valve solenoid) Long Barn: $60. 97 (Loading dock repairs) Ace Hardware: $19. 99 (Raw water valve repair) Caps for WTP: Maintenance Cap: Remaining balance is $11,683. 53. Chemical Cap: Remaining balance is $12,906. 83. Personnel Kyle Smiley: Operator (PA Class A, E, Subclass 1,10,11,12) Tony Perott: Operator (PA Class C, E, Water Subclass 1,6,7,8,12) Cody Williams: Operator in Training (PA Class E, Water Subclass 12) Shawn Jones: Operator in Training (Training for PA DEP exam) Luke Byrne: Project Manager (PA Class A, E, Water Subclass 1,7,8,10,11,12; PA Class A, E, Wastewater) Anthony Perott: Successfully passed all required subclasses and is now a fully licensed operator for the Ebensburg WTP. Upcoming Items ("On the Radar") DAF Spare parts Upper reservoir inlet valves Online turbidity instrument replacement Lagoon pump installation